<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.edrpower.com/blogs/Energy-Conservation/feed" rel="self" type="application/rss+xml"/><title>EDR POWER INTEGRATORS - Blog , Energy Conservation</title><description>EDR POWER INTEGRATORS - Blog , Energy Conservation</description><link>https://www.edrpower.com/blogs/Energy-Conservation</link><lastBuildDate>Wed, 15 Apr 2026 13:53:33 +0530</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[ISO 50001 EMS]]></title><link>https://www.edrpower.com/blogs/post/iso-50001-ems</link><description><![CDATA[ISO 50001, the global energy management systems standard,&nbsp; specifies requirements for establishing, implementing, maintaining, and improving an En ]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_XwLQ1UgAQTidoheXrMHXGw" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_dO6HwLQcRuy0pB0OT9zp9g" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_sQuGTbd0S9mKv2Y1IVfTBQ" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_Mt2QdJ_-QX6vAPN-_duKUA" data-element-type="heading" class="zpelement zpelem-heading "><style></style><h2
 class="zpheading zpheading-align-center zpheading-align-mobile-center zpheading-align-tablet-center " data-editor="true">ISO 50001 Energy Management System</h2></div>
<div data-element-id="elm_JudNHlQJT86ayU6sdvltSw" data-element-type="text" class="zpelement zpelem-text "><style></style><div class="zptext zptext-align-center zptext-align-mobile-center zptext-align-tablet-center " data-editor="true"><p></p><div><p><span>ISO 50001, the global energy management systems standard,&nbsp;<b>specifies requirements for establishing, implementing, maintaining, and improving an EnMS</b>. The standard is based upon the Plan-Do-Check-Act management system, which is familiar to many manufacturing plants that have implemented other ISO standards.</span><br/></p><p><span><br/></span></p><p></p><div style="text-align:center;"><p style="margin-bottom:12.5px;text-align:left;"><span>ISO 50001 provides a framework of requirements for organizations to:</span></p><ul><li style="text-align:left;"><span>Develop a policy for more efficient use of energy</span></li><li style="text-align:left;"><span>Fix targets and objectives to meet the policy</span></li><li style="text-align:left;"><span>Use data to better understand and make decisions about energy use</span></li><li style="text-align:left;"><span>Measure the results</span></li><li style="text-align:left;"><span>Review how well the policy works, and</span></li><li style="text-align:left;"><span>Continually improve energy management</span></li></ul></div></div><br/><p></p></div>
</div><div data-element-id="elm_sm88F5SIRHKWY18VN4o1MQ" data-element-type="button" class="zpelement zpelem-button "><style></style><div class="zpbutton-container zpbutton-align-center zpbutton-align-mobile-center zpbutton-align-tablet-center"><style type="text/css"></style><a class="zpbutton-wrapper zpbutton zpbutton-type-primary zpbutton-size-md zpbutton-style-none " href="/contact" target="_blank"><span class="zpbutton-content">Get Started Now</span></a></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Sat, 30 Aug 2025 23:08:33 +0530</pubDate></item><item><title><![CDATA[Electrical work]]></title><link>https://www.edrpower.com/blogs/post/electricalwork</link><description><![CDATA[E01 Metering Products, Nature of work: Supply, Installation, Commissioning, Testing and Calibration Trivector Meter, Maximum Demand Controller, Energy ]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_U4HY-0KxTq-2ADEy6BrdWQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_7hMAzGTEQqW76X2dGj4XXw" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"> [data-element-id="elm_7hMAzGTEQqW76X2dGj4XXw"].zprow{ border-radius:1px; } </style><div data-element-id="elm_hT_UfsWESYmtVqJmjMpZHg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_4CAG7rwBQNK8rqOLeKJz4g" data-element-type="text" class="zpelement zpelem-text "><style> [data-element-id="elm_4CAG7rwBQNK8rqOLeKJz4g"].zpelem-text { border-radius:1px; } </style><div class="zptext zptext-align-center " data-editor="true"><p style="text-align:left;">E01 Metering Products, Nature of work: Supply, Installation, Commissioning, Testing and Calibration</p><p style="text-align:left;"></p><blockquote style="margin:0px 0px 0px 40px;border:none;padding:0px;"><p style="text-align:left;">Trivector Meter, Maximum Demand Controller, Energy Meter, Multifunction Meter, MW Meter, Smart Meter, Smart load manager, Ammeter, Voltmeter, Power factor Meter, Power Meter, Power Quality Meter, Power Factor Controller (Auto / Manual), Single Phase Static Meter, Three Phase Static Meter, Bi-direction Energy Meter, DC Voltmeter, DC Ammeter, DC Energy Meter.</p></blockquote><br><p></p><p style="text-align:left;">E02 Control Panel,&nbsp;<span style="color:inherit;text-align:center;">Nature of work: Supply, Designing, Detail Engineering, Manufacturing, Installation, Commissioning, Testing.</span></p><blockquote style="margin:0px 0px 0px 40px;border:none;padding:0px;"><p style="text-align:left;"><span style="color:inherit;text-align:center;">APFC Panel, Power Factor Correction Panel, Thyristor / SCR based Power factor correction Panel, Harmonics Filter, VFD Drive Panel, PLC Automation control Panel, Heater Control Panel ( SCR / Contactor), Thyristor Power Controller, SCR Controlled Battery Charger, LT Control Panel</span></p></blockquote><p style="text-align:left;"><span style="color:inherit;text-align:center;"><br></span></p><p style="text-align:left;"><span style="color:inherit;text-align:center;">E03 SCADA Software, Nature of work:&nbsp;</span><span style="color:inherit;text-align:center;">Supply, Designing, Detail Engineering, Manufacturing, Installation, Commissioning</span></p><blockquote style="margin:0px 0px 0px 40px;border:none;padding:0px;"><p style="text-align:left;"><span style="text-align:center;"><span style="color:inherit;">EMS - Energy Monitoring System, Energy Management system, Water Flow Monitoring System, Building </span>Management<span style="color:inherit;">&nbsp;System, Solar Monitoring System, Smart lighting Automation System, Battery Monitoring System, Temperature Data logging, Process Monitoring System.</span></span></p><p style="text-align:left;"><span style="text-align:center;"><span style="color:inherit;"><br></span></span></p></blockquote><div style="text-align:left;">E04 Cables, Nature of work: Supply, Installation, Commissioning</div><div style="text-align:left;"><blockquote style="margin:0px 0px 0px 40px;border:none;padding:0px;"><div style="text-align:left;">RS485 Communication cable, Instrumentation cable, control cable, Fiber optic cable, Ethernet cable, Network cable</div><div style="text-align:left;"><br></div></blockquote>E05 Relays,&nbsp;<span style="color:inherit;text-align:center;">Nature of work: Supply,&nbsp;</span><span style="color:inherit;text-align:center;">Manufacturing, </span><span style="color:inherit;text-align:center;">Installation, Commissioning, Testing, Calibration</span></div><blockquote style="margin:0px 0px 0px 40px;border:none;padding:0px;"><div style="text-align:left;"><span style="color:inherit;text-align:center;">Numeric direction Relay , AC Voltage Controller (over voltage / under voltage), AC Current Controller(Over current, Unbalanced, Reverse),&nbsp;</span><span style="color:inherit;text-align:center;">Over current Relay, Earth Fault Relay, Power Factor control Relay, Power Relay.</span></div><div style="text-align:left;"><span style="color:inherit;text-align:center;"><br></span></div></blockquote><div style="text-align:left;">E06 Electrical Accessories</div><div style="text-align:left;"><blockquote style="margin:0px 0px 0px 40px;border:none;padding:0px;"><div style="text-align:left;">Current Transformer ( LT CT 5A/1A), Thyristor Module, Capacitor Duty Contactor, Power Contactor, Capacitor, Reactor , Line choke, Etc.</div></blockquote></div></div>
</div><div data-element-id="elm_vZdUfFJCTQiZW-ZRaxWKcw" data-element-type="button" class="zpelement zpelem-button "><style> [data-element-id="elm_vZdUfFJCTQiZW-ZRaxWKcw"].zpelem-button{ border-radius:1px; } </style><div class="zpbutton-container zpbutton-align-center "><style type="text/css"></style><a class="zpbutton-wrapper zpbutton zpbutton-type-primary zpbutton-size-md zpbutton-style-none " href="/contact"><span class="zpbutton-content">Contact us</span></a></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Mon, 16 Sep 2024 11:00:04 +0530</pubDate></item><item><title><![CDATA[Smart DC Energy Meter]]></title><link>https://www.edrpower.com/blogs/post/smart-dc-energy-meter</link><description><![CDATA[Download Technical Specification&nbsp; ]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_ZN9ZeX8nRtaK1P0f9p1LDQ" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_0lrZFnMKRu6ArhG4sTFCAg" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_JKnGPG65TwiKdun4LOHHAw" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_sHXzjFjGRKCwokG302g3sQ" data-element-type="text" class="zpelement zpelem-text "><style> [data-element-id="elm_sHXzjFjGRKCwokG302g3sQ"].zpelem-text { border-radius:1px; } </style><div class="zptext zptext-align-center " data-editor="true"><p>Download Technical Specification&nbsp;</p></div>
</div><div data-element-id="elm_q78ApTwCRti9aIDqx2nIZg" data-element-type="button" class="zpelement zpelem-button "><style> [data-element-id="elm_q78ApTwCRti9aIDqx2nIZg"].zpelem-button{ border-radius:1px; } </style><div class="zpbutton-container zpbutton-align-center "><style type="text/css"></style><a class="zpbutton-wrapper zpbutton zpbutton-type-primary zpbutton-size-md zpbutton-style-none " href="/Technical%20Specification/EDR%20DCM%209603%20Model%20Specification.pdf" download target="_blank"><span class="zpbutton-content">Download</span></a></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Wed, 05 Apr 2023 19:55:36 +0530</pubDate></item><item><title><![CDATA[Energy Study & Power Quality Analysis with EDR Engineer]]></title><link>https://www.edrpower.com/blogs/post/energy-study</link><description><![CDATA[EDR Power Integrators, we are passionate about helping industries optimize their energy usage and reduce costs. As part of our commitment to customer ]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_JtyDjLAlSrCY1JU_RPvYEg" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_DtNyXpeyRluhY29944xvSQ" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_zOHyqlrjTxeS0MBNHWEMvw" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_0AKMq7fHRaaRFzXwBfeQcA" data-element-type="heading" class="zpelement zpelem-heading "><style> [data-element-id="elm_0AKMq7fHRaaRFzXwBfeQcA"].zpelem-heading { border-radius:1px; } </style><h2
 class="zpheading zpheading-align-center " data-editor="true"><div style="color:inherit;"><p><span style="font-size:18pt;">On-Site Study with EDR Engineers: Optimize Your Energy Usage and Reduce Costs</span></p></div></h2></div>
<div data-element-id="elm_ZGV-xRQ4SICVBzNYmGQG4Q" data-element-type="text" class="zpelement zpelem-text "><style> [data-element-id="elm_ZGV-xRQ4SICVBzNYmGQG4Q"].zpelem-text { border-radius:1px; } </style><div class="zptext zptext-align-center " data-editor="true"><div style="color:inherit;"><div style="color:inherit;"><div style="color:inherit;"><ul><ul><li style="text-align:left;"><span style="font-size:18px;font-family:&quot;Open Sans&quot;, sans-serif;">EDR Power Integrators, we are passionate about helping industries optimize their energy usage and reduce costs. As part of our commitment to customer satisfaction, we offer a comprehensive site study for energy measurement, power quality analysis, and suggestions for energy conservation techniques.</span></li><li style="text-align:left;"><span style="font-family:&quot;Open Sans&quot;, sans-serif;">Our team of experienced engineers will visit your site to conduct a thorough analysis of your energy usage and identify areas where energy is being wasted. We use state-of-the-art equipment to measure energy usage and power quality, and our team will provide you with a detailed report of their findings, along with recommendations for improvement.</span></li><li style="text-align:left;"><span style="font-family:&quot;Open Sans&quot;, sans-serif;">Our site study is an invaluable tool for any business looking to optimize its energy usage and reduce costs. It provides a roadmap for implementing energy-efficient practices and can help businesses save money on energy costs over the long term.</span></li><li style="text-align:left;"><span style="font-family:&quot;Open Sans&quot;, sans-serif;">At EDR Power Integrators, we believe in delivering high-quality products and services that meet or exceed customer expectations. We pride ourselves on our exceptional customer service and are always available to answer any questions or provide support.</span></li><li style="text-align:left;"><span style="font-family:&quot;Open Sans&quot;, sans-serif;">If you're interested in learning more about our site study services, please contact us today to schedule an appointment. We look forward to helping you optimize your energy usage and reduce costs.</span></li></ul></ul></div></div></div></div>
</div><div data-element-id="elm_diItAB0UQvOgtqYweP-SEg" data-element-type="button" class="zpelement zpelem-button "><style> [data-element-id="elm_diItAB0UQvOgtqYweP-SEg"].zpelem-button{ border-radius:1px; } </style><div class="zpbutton-container zpbutton-align-center "><style type="text/css"></style><a class="zpbutton-wrapper zpbutton zpbutton-type-primary zpbutton-size-md zpbutton-style-none " href="/contact" target="_blank"><span class="zpbutton-content">Get Started Now</span></a></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 14 Mar 2023 22:42:26 +0530</pubDate></item><item><title><![CDATA[AMI Smart Metering]]></title><link>https://www.edrpower.com/blogs/post/ami-smart-metering</link><description><![CDATA[Smart Meter it supports active &amp; reactive energy, measurement, instantaneous measurement of Voltage, Current, Power, Demand, Frequency, Power fact ]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_iWvqpAfASVqX-F2Y3jWpug" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_hHV6QT_-TgmMCrTuHBZE2w" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_bUjOuTECR2mt0PAXm5dSNw" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_DWceGrJXSSqIP5w9ijvKww" data-element-type="heading" class="zpelement zpelem-heading "><style> [data-element-id="elm_DWceGrJXSSqIP5w9ijvKww"].zpelem-heading { border-radius:1px; } </style><h2
 class="zpheading zpheading-align-center " data-editor="true"><span style="font-size:24px;">Pre-paid / Post-paid Smart Meter</span></h2></div>
<div data-element-id="elm_97fOp_MbQnmsBXCDAYdR2g" data-element-type="text" class="zpelement zpelem-text "><style> [data-element-id="elm_97fOp_MbQnmsBXCDAYdR2g"].zpelem-text { border-radius:1px; } </style><div class="zptext zptext-align-center " data-editor="true"><p style="text-align:justify;">Smart Meter it supports active &amp; reactive energy, measurement, instantaneous measurement of Voltage, Current, Power, Demand, Frequency, Power factor, relay disconnection &amp; reconnection management, pre-paid to post-paid conversion or vice-versa. with an optional plug-and-play RF/GPRS (2G/3G/4G LTE)/PLC communication module, the meter can be used in sophisticated AMI, vending system, Utility billing.</p><p style="text-align:justify;">Main Features:</p><p style="text-align:justify;"><span style="font-family:Roboto, sans-serif;font-size:14px;">- Complying to IS 16444 standards for metering requirements.</span></p><p style="text-align:justify;"><span style="font-family:Roboto, sans-serif;font-size:14px;">- Complying IS 159159 part-2 standard for DLMS.</span></p><p style="text-align:justify;"><span style="font-family:Roboto, sans-serif;font-size:14px;">- Bidirectional measurement of instantaneous, energy and demand parameters.</span></p><p style="text-align:justify;"><span style="font-family:Roboto, sans-serif;font-size:14px;">- Data logging for instantaneous parameters, billing parameters and block load profile.</span></p><p style="text-align:justify;"><span style="font-family:Roboto, sans-serif;font-size:14px;">- Tamper event detection, recording and reporting.</span></p><p style="text-align:justify;"><span style="font-family:Roboto, sans-serif;font-size:14px;">- Power fail alerts, Over current connect / disconnect through latching relay</span></p><p style="text-align:justify;"><span style="font-family:Roboto, sans-serif;font-size:14px;">- Remote firmware upgrade</span></p></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Wed, 11 Jan 2023 19:06:48 +0530</pubDate></item><item><title><![CDATA[Main Points Remember in Harmonics (Electrical Power)]]></title><link>https://www.edrpower.com/blogs/post/harmonics-filter</link><description><![CDATA[Main Points Remember in Harmonics (Electrical Power) ** Harmonics current and voltage are generated by non-linear loads ** Harmonics distortion is a for ]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_ZH52aB1QQuiRN5hsSQjO9A" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_e796LqUcR_mlH5DFv9r8-w" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"> [data-element-id="elm_e796LqUcR_mlH5DFv9r8-w"].zprow{ border-radius:1px; } </style><div data-element-id="elm_CWrXjjRISZ6WaQ8KGz7tzw" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_Fe-W8OgCRqisYz7YcdtQoQ" data-element-type="text" class="zpelement zpelem-text "><style> [data-element-id="elm_Fe-W8OgCRqisYz7YcdtQoQ"].zpelem-text { border-radius:1px; } </style><div class="zptext zptext-align-center " data-editor="true"><div style="color:inherit;"><h1 style="text-align:left;line-height:1;"><span style="font-size:14px;background-color:rgb(116, 220, 168);">Main Points Remember in Harmonics (Electrical Power)</span></h1></div><div style="text-align:left;"></div><p style="line-height:1;"></p><div style="text-align:left;"><span style="font-size:14px;color:inherit;">** Harmonics current and voltage are generated by non-linear loads</span></div><div style="text-align:left;"><span style="font-size:14px;color:inherit;">** Harmonics distortion is a form of pollution</span></div><div style="text-align:left;"><span style="font-size:14px;color:inherit;">** Dedicated standards specify the limits ( IEE 51, IEC/EN 61800-3)</span></div><div style="text-align:left;"><span style="font-size:14px;color:inherit;">Sources of Harmonics: Variable Speed AC/DC drives(VFD), UPS Systems, Rectifier, SMPS, Static converter, Thyristor controlled systems Frequency controlled Induction Furnaces, Arc Furnaces, Welding, lighting, When saturation is reached in Transformers, Motors, Generators.</span></div><p><span style="color:inherit;"><a href="https://www.linkedin.com/feed/hashtag/?keywords=powerdistribution&amp;highlightedUpdateUrns=urn%3Ali%3Aactivity%3A6949257698265681920">#powerdistribution</a><span style="font-size:14px;">&nbsp;</span><a href="https://www.linkedin.com/feed/hashtag/?keywords=electrical&amp;highlightedUpdateUrns=urn%3Ali%3Aactivity%3A6949257698265681920">#electrical</a><span style="font-size:14px;">&nbsp;</span><a href="https://www.linkedin.com/feed/hashtag/?keywords=harmonics&amp;highlightedUpdateUrns=urn%3Ali%3Aactivity%3A6949257698265681920">#harmonics</a><span style="font-size:14px;">&nbsp;</span><a href="https://www.linkedin.com/feed/hashtag/?keywords=ems&amp;highlightedUpdateUrns=urn%3Ali%3Aactivity%3A6949257698265681920">#ems</a><span style="font-size:14px;">&nbsp;</span><a href="https://www.linkedin.com/feed/hashtag/?keywords=energyefficiency&amp;highlightedUpdateUrns=urn%3Ali%3Aactivity%3A6949257698265681920">#energyefficiency</a><span style="font-size:14px;">&nbsp;</span><a href="https://www.linkedin.com/feed/hashtag/?keywords=energymanagement&amp;highlightedUpdateUrns=urn%3Ali%3Aactivity%3A6949257698265681920">#energymanagement</a><span style="font-size:14px;">&nbsp;</span><a href="https://www.linkedin.com/feed/hashtag/?keywords=energymonitoring&amp;highlightedUpdateUrns=urn%3Ali%3Aactivity%3A6949257698265681920">#energymonitoring</a><span style="font-size:14px;">&nbsp;</span><a href="https://www.linkedin.com/feed/hashtag/?keywords=energymanagementsystem&amp;highlightedUpdateUrns=urn%3Ali%3Aactivity%3A6949257698265681920">#energymanagementsystem</a></span><br></p><p></p></div>
</div><div data-element-id="elm_xkV-cK1sQ9OoO7XsuvpzMA" data-element-type="button" class="zpelement zpelem-button "><style> [data-element-id="elm_xkV-cK1sQ9OoO7XsuvpzMA"].zpelem-button{ border-radius:1px; } </style><div class="zpbutton-container zpbutton-align-center "><style type="text/css"></style><a class="zpbutton-wrapper zpbutton zpbutton-type-primary zpbutton-size-sm zpbutton-style-none " href="mailto:technical@edrpower.com?subject=Enquiry%20-%20Harmonics%20Filter&amp;cc=edrtechnical@gmail.com"><span class="zpbutton-content">For Enquiry Click to Email</span></a></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Sun, 03 Jul 2022 12:56:14 +0530</pubDate></item><item><title><![CDATA[Energy Conservation and Efficiency Optimization techniques]]></title><link>https://www.edrpower.com/blogs/post/energy-conservation-and-efficiency-optimization-techniques</link><description><![CDATA[Energy conserved and saved is equivalent to energy generated. Spending on Energy conservation not only reduces energy bills, but same precious natural ]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_EaNRKGnlQOSVdwUyvRR60w" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_PznEJp5ITSy-ZBIY8lMU9Q" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_v0_1nENXRIO6CRrPCMxSvg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_X9MKohjCTYmM5Em2ZX3zNQ" data-element-type="heading" class="zpelement zpelem-heading "><style> [data-element-id="elm_X9MKohjCTYmM5Em2ZX3zNQ"].zpelem-heading { border-radius:1px; } </style><h6
 class="zpheading zpheading-style-none zpheading-align-center " data-editor="true"><span style="font-size:24px;">We should Address the challenges, effects and solutions.&nbsp;</span><span style="font-size:20px;"><br>​Power is among the most critical component of infrastructure crucial for the economic growth and welfare of nations.</span><br></h6></div>
<div data-element-id="elm_AvblNbQHR8OTTnjS83T-Eg" data-element-type="text" class="zpelement zpelem-text "><style> [data-element-id="elm_AvblNbQHR8OTTnjS83T-Eg"].zpelem-text { border-radius:1px; } </style><div class="zptext zptext-align-center " data-editor="true"><p style="text-align:justify;">Energy conserved and saved is equivalent to energy generated. Spending on Energy conservation not only reduces energy bills, but same precious natural resources and reduce investments required in additional power generation capacity. In 2050 the world economy will be four time as large as today, generating an 80% increase in the amount of energy we consume. The energy intensity per square meter of the global building sector needs to improve on average by 30% by 2030 (Compared to 2015) to be on track to meet global climate ambitious set forth in the paris agreement.</p><p style="text-align:justify;"><br></p><p style="text-align:justify;">Power in India, India is the 3rd largest Producer and 2nd largest consumer of electricity in world. Installed Generation capacity is 393 GW as of Dec 2021. and demand increasing 8% average year by year. Power is among the most critical component of infrastructure crucial for the economic growth and welfare of nations.</p><p style="text-align:justify;"><br></p><p style="text-align:justify;">We should address the challenges, effects and solution.</p><blockquote style="margin:0px 0px 0px 40px;border:none;padding:0px;"><p style="text-align:justify;">1. Power Quality Monitoring ( what we can't measure we can't manage it)</p><p style="text-align:justify;">2. Energy Management System</p><p style="text-align:justify;">3. Power factor correction System</p><p style="text-align:justify;">4. Harmonics Mitigation</p><p style="text-align:justify;">5. Variable Speed Drives</p><p style="text-align:justify;">6. Thyristor Power Controller&nbsp;</p><p style="text-align:justify;">7. Energy Efficient Equipment</p><p style="text-align:justify;">8. Smart devices and Controllers</p><p style="text-align:justify;">9. Process Monitoring System</p><p style="text-align:justify;">10. Renewable and Waste energy conversion</p></blockquote></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Mon, 31 Jan 2022 14:09:19 +0530</pubDate></item></channel></rss>