<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.edrpower.com/blogs/tag/ems/feed" rel="self" type="application/rss+xml"/><title>EDR POWER INTEGRATORS - Blog #EMS</title><description>EDR POWER INTEGRATORS - Blog #EMS</description><link>https://www.edrpower.com/blogs/tag/ems</link><lastBuildDate>Wed, 15 Apr 2026 13:45:42 +0530</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[ISO 50001 EMS]]></title><link>https://www.edrpower.com/blogs/post/iso-50001-ems</link><description><![CDATA[ISO 50001, the global energy management systems standard,&nbsp; specifies requirements for establishing, implementing, maintaining, and improving an En ]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_XwLQ1UgAQTidoheXrMHXGw" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_dO6HwLQcRuy0pB0OT9zp9g" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_sQuGTbd0S9mKv2Y1IVfTBQ" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_Mt2QdJ_-QX6vAPN-_duKUA" data-element-type="heading" class="zpelement zpelem-heading "><style></style><h2
 class="zpheading zpheading-align-center zpheading-align-mobile-center zpheading-align-tablet-center " data-editor="true">ISO 50001 Energy Management System</h2></div>
<div data-element-id="elm_JudNHlQJT86ayU6sdvltSw" data-element-type="text" class="zpelement zpelem-text "><style></style><div class="zptext zptext-align-center zptext-align-mobile-center zptext-align-tablet-center " data-editor="true"><p></p><div><p><span>ISO 50001, the global energy management systems standard,&nbsp;<b>specifies requirements for establishing, implementing, maintaining, and improving an EnMS</b>. The standard is based upon the Plan-Do-Check-Act management system, which is familiar to many manufacturing plants that have implemented other ISO standards.</span><br/></p><p><span><br/></span></p><p></p><div style="text-align:center;"><p style="margin-bottom:12.5px;text-align:left;"><span>ISO 50001 provides a framework of requirements for organizations to:</span></p><ul><li style="text-align:left;"><span>Develop a policy for more efficient use of energy</span></li><li style="text-align:left;"><span>Fix targets and objectives to meet the policy</span></li><li style="text-align:left;"><span>Use data to better understand and make decisions about energy use</span></li><li style="text-align:left;"><span>Measure the results</span></li><li style="text-align:left;"><span>Review how well the policy works, and</span></li><li style="text-align:left;"><span>Continually improve energy management</span></li></ul></div></div><br/><p></p></div>
</div><div data-element-id="elm_sm88F5SIRHKWY18VN4o1MQ" data-element-type="button" class="zpelement zpelem-button "><style></style><div class="zpbutton-container zpbutton-align-center zpbutton-align-mobile-center zpbutton-align-tablet-center"><style type="text/css"></style><a class="zpbutton-wrapper zpbutton zpbutton-type-primary zpbutton-size-md zpbutton-style-none " href="/contact" target="_blank"><span class="zpbutton-content">Get Started Now</span></a></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Sat, 30 Aug 2025 23:08:33 +0530</pubDate></item><item><title><![CDATA[Energy Study & Power Quality Analysis with EDR Engineer]]></title><link>https://www.edrpower.com/blogs/post/energy-study</link><description><![CDATA[EDR Power Integrators, we are passionate about helping industries optimize their energy usage and reduce costs. As part of our commitment to customer ]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_JtyDjLAlSrCY1JU_RPvYEg" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_DtNyXpeyRluhY29944xvSQ" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_zOHyqlrjTxeS0MBNHWEMvw" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_0AKMq7fHRaaRFzXwBfeQcA" data-element-type="heading" class="zpelement zpelem-heading "><style> [data-element-id="elm_0AKMq7fHRaaRFzXwBfeQcA"].zpelem-heading { border-radius:1px; } </style><h2
 class="zpheading zpheading-align-center " data-editor="true"><div style="color:inherit;"><p><span style="font-size:18pt;">On-Site Study with EDR Engineers: Optimize Your Energy Usage and Reduce Costs</span></p></div></h2></div>
<div data-element-id="elm_ZGV-xRQ4SICVBzNYmGQG4Q" data-element-type="text" class="zpelement zpelem-text "><style> [data-element-id="elm_ZGV-xRQ4SICVBzNYmGQG4Q"].zpelem-text { border-radius:1px; } </style><div class="zptext zptext-align-center " data-editor="true"><div style="color:inherit;"><div style="color:inherit;"><div style="color:inherit;"><ul><ul><li style="text-align:left;"><span style="font-size:18px;font-family:&quot;Open Sans&quot;, sans-serif;">EDR Power Integrators, we are passionate about helping industries optimize their energy usage and reduce costs. As part of our commitment to customer satisfaction, we offer a comprehensive site study for energy measurement, power quality analysis, and suggestions for energy conservation techniques.</span></li><li style="text-align:left;"><span style="font-family:&quot;Open Sans&quot;, sans-serif;">Our team of experienced engineers will visit your site to conduct a thorough analysis of your energy usage and identify areas where energy is being wasted. We use state-of-the-art equipment to measure energy usage and power quality, and our team will provide you with a detailed report of their findings, along with recommendations for improvement.</span></li><li style="text-align:left;"><span style="font-family:&quot;Open Sans&quot;, sans-serif;">Our site study is an invaluable tool for any business looking to optimize its energy usage and reduce costs. It provides a roadmap for implementing energy-efficient practices and can help businesses save money on energy costs over the long term.</span></li><li style="text-align:left;"><span style="font-family:&quot;Open Sans&quot;, sans-serif;">At EDR Power Integrators, we believe in delivering high-quality products and services that meet or exceed customer expectations. We pride ourselves on our exceptional customer service and are always available to answer any questions or provide support.</span></li><li style="text-align:left;"><span style="font-family:&quot;Open Sans&quot;, sans-serif;">If you're interested in learning more about our site study services, please contact us today to schedule an appointment. We look forward to helping you optimize your energy usage and reduce costs.</span></li></ul></ul></div></div></div></div>
</div><div data-element-id="elm_diItAB0UQvOgtqYweP-SEg" data-element-type="button" class="zpelement zpelem-button "><style> [data-element-id="elm_diItAB0UQvOgtqYweP-SEg"].zpelem-button{ border-radius:1px; } </style><div class="zpbutton-container zpbutton-align-center "><style type="text/css"></style><a class="zpbutton-wrapper zpbutton zpbutton-type-primary zpbutton-size-md zpbutton-style-none " href="/contact" target="_blank"><span class="zpbutton-content">Get Started Now</span></a></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 14 Mar 2023 22:42:26 +0530</pubDate></item><item><title><![CDATA[Multifunction Meter/ Energy Meter Model Selection]]></title><link>https://www.edrpower.com/blogs/post/energymeter</link><description><![CDATA[MFM9112, MFM9212, MFM9012, MFM9013,MFM9113, MFM9014, MFM901, EM9024, MFM9022, MFM9500, MFM9501, MFM9502, APM7500, EM9005, DEM9004, DEM9004F, PWT9060V, ]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_d5__eIMRSAKgUUyikuqU-Q" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_LRZWElBhTze5bSDh2RYkeQ" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"> [data-element-id="elm_LRZWElBhTze5bSDh2RYkeQ"].zprow{ border-radius:1px; } </style><div data-element-id="elm_oc8rAa80TJOrKrSdineRdw" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"> [data-element-id="elm_oc8rAa80TJOrKrSdineRdw"].zpelem-col{ border-radius:1px; } </style><div data-element-id="elm_NxczS7LTs1kdGviw3myTHQ" data-element-type="table" class="zpelement zpelem-table "><style type="text/css"> [data-element-id="elm_NxczS7LTs1kdGviw3myTHQ"].zpelem-table{ border-radius:1px; } [data-element-id="elm_NxczS7LTs1kdGviw3myTHQ"] .zptable{ width:100% !important; } </style><div class="zptable zptable-align-left zptable-header- zptable-header-none zptable-cell-outline-on zptable-outline-on zptable-style- " data-width="100" data-editor="true"><table style="width:100%;"><tbody><tr><td style="width:21%;"><span style="text-decoration-line:underline;">Instrument Description</span></td><td style="width:80%;"><span style="text-decoration-line:underline;">Model No</span></td></tr><tr><td style="width:21%;"> Multifunction Meter Model</td><td style="width:80%;"> MFM 9212, MFM 9213, MFM 9112, MFM 9012, MFM 9013, MFM 9014, MFM 9015, MFM 9011, MFM 9011</td></tr><tr><td style="width:21%;"> Power Genius Model</td><td style="width:80%;">MFM 9500, MFM 9501, MFM 9502</td></tr><tr><td style="width:21%;">Power Matrix</td><td style="width:80%;">APM 7500</td></tr><tr><td style="width:21%;"> Maximum Demand Controller</td><td style="width:80%;"> PCM 9504, PCM 9505, PCM 9506, PCM 7504, PCM 9006</td></tr><tr><td style="width:21%;">Panel Meter</td><td style="width:80%;">VAF 9000, EM 9005, VLT 9053, AMM 9043, VLT 9059, AMM 9049</td></tr><tr><td style="width:21%;"> DC Energy Meter</td><td style="width:80%;">DEM 9004F</td></tr><tr><td style="width:21%;">Dual Source Energy Meter</td><td style="width:80%;"> EM 9024, MFM 9022, MFM 9023, MFM 9022 NXT, MFM 9023 NXT</td></tr><tr><td style="width:21%;">Power Factor Controller</td><td style="width:80%;">PFC 9059, PFC 9059R, PFC 9055, PFC 9055R, PFC 9070, PFC 9070R</td></tr><tr><td style="width:21%;">Transducer</td><td style="width:80%;" class="zp-selected-cell">PWT 9060V, PWT 9060A, PWT9060F, PWT 9060P, MFM 9060</td></tr></tbody></table></div>
</div></div><div data-element-id="elm_Q-C5dmf4vV2HCMraEuY49Q" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- zpdefault-section zpdefault-section-bg "><style type="text/css"> [data-element-id="elm_Q-C5dmf4vV2HCMraEuY49Q"].zpelem-col{ border-radius:1px; } </style><div data-element-id="elm_dyLL3AgKMMBnvbLuc-jiAQ" data-element-type="text" class="zpelement zpelem-text "><style> [data-element-id="elm_dyLL3AgKMMBnvbLuc-jiAQ"].zpelem-text { border-radius:1px; } </style><div class="zptext zptext-align-left " data-editor="true"><p>MFM9112, MFM9212, MFM9012, MFM9013,MFM9113, MFM9014, MFM901, EM9024, MFM9022, MFM9500, MFM9501, MFM9502, APM7500, EM9005, DEM9004, DEM9004F, PWT9060V, PWT9060A, PWT9060F, PWT9060F, MFM9060, PFC9059, PF9055, PFC9070, VAF9000, VLT9053, AMM9043</p></div>
</div></div></div><div data-element-id="elm_XA5igYAxxhYkhZ2ttUnzsw" data-element-type="row" class="zprow zprow-container zpalign-items-flex-start zpjustify-content-flex-start zpdefault-section zpdefault-section-bg " data-equal-column=""><style type="text/css"> [data-element-id="elm_XA5igYAxxhYkhZ2ttUnzsw"].zprow{ border-radius:1px; } </style><div data-element-id="elm_ceGmIdxMFEGogdEcf-hzVw" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- zpdefault-section zpdefault-section-bg "><style type="text/css"> [data-element-id="elm_ceGmIdxMFEGogdEcf-hzVw"].zpelem-col{ border-radius:1px; } </style></div>
</div></div></div><div data-element-id="elm_q687SHsaQU570gkEKV7zqg" data-element-type="section" class="zpsection zpdefault-section zpdefault-section-bg "><style type="text/css"> [data-element-id="elm_q687SHsaQU570gkEKV7zqg"].zpsection{ border-radius:1px; } </style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_RxVLXdBKlJreBBNXZBxhDg" data-element-type="row" class="zprow zprow-container zpalign-items-flex-start zpjustify-content-flex-start zpdefault-section zpdefault-section-bg " data-equal-column=""><style type="text/css"> [data-element-id="elm_RxVLXdBKlJreBBNXZBxhDg"].zprow{ border-radius:1px; } </style><div data-element-id="elm_G2pSBwyZBdTlLO8-E5ZEhg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- zpdefault-section zpdefault-section-bg "><style type="text/css"> [data-element-id="elm_G2pSBwyZBdTlLO8-E5ZEhg"].zpelem-col{ border-radius:1px; } </style></div>
</div></div></div></div> ]]></content:encoded><pubDate>Tue, 20 Dec 2022 22:39:09 +0530</pubDate></item><item><title><![CDATA[Main Points Remember in Harmonics (Electrical Power)]]></title><link>https://www.edrpower.com/blogs/post/harmonics-filter</link><description><![CDATA[Main Points Remember in Harmonics (Electrical Power) ** Harmonics current and voltage are generated by non-linear loads ** Harmonics distortion is a for ]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_ZH52aB1QQuiRN5hsSQjO9A" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_e796LqUcR_mlH5DFv9r8-w" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"> [data-element-id="elm_e796LqUcR_mlH5DFv9r8-w"].zprow{ border-radius:1px; } </style><div data-element-id="elm_CWrXjjRISZ6WaQ8KGz7tzw" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_Fe-W8OgCRqisYz7YcdtQoQ" data-element-type="text" class="zpelement zpelem-text "><style> [data-element-id="elm_Fe-W8OgCRqisYz7YcdtQoQ"].zpelem-text { border-radius:1px; } </style><div class="zptext zptext-align-center " data-editor="true"><div style="color:inherit;"><h1 style="text-align:left;line-height:1;"><span style="font-size:14px;background-color:rgb(116, 220, 168);">Main Points Remember in Harmonics (Electrical Power)</span></h1></div><div style="text-align:left;"></div><p style="line-height:1;"></p><div style="text-align:left;"><span style="font-size:14px;color:inherit;">** Harmonics current and voltage are generated by non-linear loads</span></div><div style="text-align:left;"><span style="font-size:14px;color:inherit;">** Harmonics distortion is a form of pollution</span></div><div style="text-align:left;"><span style="font-size:14px;color:inherit;">** Dedicated standards specify the limits ( IEE 51, IEC/EN 61800-3)</span></div><div style="text-align:left;"><span style="font-size:14px;color:inherit;">Sources of Harmonics: Variable Speed AC/DC drives(VFD), UPS Systems, Rectifier, SMPS, Static converter, Thyristor controlled systems Frequency controlled Induction Furnaces, Arc Furnaces, Welding, lighting, When saturation is reached in Transformers, Motors, Generators.</span></div><p><span style="color:inherit;"><a href="https://www.linkedin.com/feed/hashtag/?keywords=powerdistribution&amp;highlightedUpdateUrns=urn%3Ali%3Aactivity%3A6949257698265681920">#powerdistribution</a><span style="font-size:14px;">&nbsp;</span><a href="https://www.linkedin.com/feed/hashtag/?keywords=electrical&amp;highlightedUpdateUrns=urn%3Ali%3Aactivity%3A6949257698265681920">#electrical</a><span style="font-size:14px;">&nbsp;</span><a href="https://www.linkedin.com/feed/hashtag/?keywords=harmonics&amp;highlightedUpdateUrns=urn%3Ali%3Aactivity%3A6949257698265681920">#harmonics</a><span style="font-size:14px;">&nbsp;</span><a href="https://www.linkedin.com/feed/hashtag/?keywords=ems&amp;highlightedUpdateUrns=urn%3Ali%3Aactivity%3A6949257698265681920">#ems</a><span style="font-size:14px;">&nbsp;</span><a href="https://www.linkedin.com/feed/hashtag/?keywords=energyefficiency&amp;highlightedUpdateUrns=urn%3Ali%3Aactivity%3A6949257698265681920">#energyefficiency</a><span style="font-size:14px;">&nbsp;</span><a href="https://www.linkedin.com/feed/hashtag/?keywords=energymanagement&amp;highlightedUpdateUrns=urn%3Ali%3Aactivity%3A6949257698265681920">#energymanagement</a><span style="font-size:14px;">&nbsp;</span><a href="https://www.linkedin.com/feed/hashtag/?keywords=energymonitoring&amp;highlightedUpdateUrns=urn%3Ali%3Aactivity%3A6949257698265681920">#energymonitoring</a><span style="font-size:14px;">&nbsp;</span><a href="https://www.linkedin.com/feed/hashtag/?keywords=energymanagementsystem&amp;highlightedUpdateUrns=urn%3Ali%3Aactivity%3A6949257698265681920">#energymanagementsystem</a></span><br></p><p></p></div>
</div><div data-element-id="elm_xkV-cK1sQ9OoO7XsuvpzMA" data-element-type="button" class="zpelement zpelem-button "><style> [data-element-id="elm_xkV-cK1sQ9OoO7XsuvpzMA"].zpelem-button{ border-radius:1px; } </style><div class="zpbutton-container zpbutton-align-center "><style type="text/css"></style><a class="zpbutton-wrapper zpbutton zpbutton-type-primary zpbutton-size-sm zpbutton-style-none " href="mailto:technical@edrpower.com?subject=Enquiry%20-%20Harmonics%20Filter&amp;cc=edrtechnical@gmail.com"><span class="zpbutton-content">For Enquiry Click to Email</span></a></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Sun, 03 Jul 2022 12:56:14 +0530</pubDate></item><item><title><![CDATA[Edge Computing in Digital Transformation]]></title><link>https://www.edrpower.com/blogs/post/Edge-Computing-in-Digital-Transformation-IIOT-4.0</link><description><![CDATA[<img align="left" hspace="5" src="https://www.edrpower.com/images/52e7d3434855aa14f6da8c7dda79367f103cd9ed55536c48732f79d59f4dc75fbc_1280.jpg"/>Digital transformation is a key component of every modern business strategy today, regardless of industry. Digital transformation initiatives enable k ]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_O1AMNeCCRcqzJAP58_BZ6g" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_-0awARhyRjWB6nyEHBS52g" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_QdDVvvV3QSC9W_QW697Neg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_8td-Qe30QiiDRFlO_ihegg" data-element-type="heading" class="zpelement zpelem-heading "><style> [data-element-id="elm_8td-Qe30QiiDRFlO_ihegg"].zpelem-heading { border-radius:1px; } </style><h2
 class="zpheading zpheading-align-center " data-editor="true">Monitoring &amp; Control, Data Collection &amp; Analysis - IoT and IIoT 4.0&nbsp;</h2></div>
<div data-element-id="elm_HG_ChZXKTqSHqLWqZgdjlA" data-element-type="text" class="zpelement zpelem-text "><style> [data-element-id="elm_HG_ChZXKTqSHqLWqZgdjlA"].zpelem-text { border-radius:1px; } </style><div class="zptext zptext-align-left " data-editor="true"><p style="text-align:left;"><span style="color:inherit;">Digital transformation is a key component of every modern business strategy today, regardless of industry. Digital transformation initiatives enable key capabilities and deliver benefits including business agility, operational efficiency, advanced analytics, and process automation, among others. Several technology trends, driving digital transformation include:&nbsp;&nbsp;<br></span></p><p style="text-align:left;"><span style="color:inherit;"><br></span></p><p style="text-align:left;"><span style="color:inherit;">A leading global research firm forecasts that by 2022, approximately 75 percent of all data will need analysis and action at the edge.&nbsp;</span><span style="color:inherit;text-align:center;">By 2025, 175 zettabytes (or 175 trillion gigabytes) of data will be generated around the globe and edge devices will create more than 90 zettabytes of that data, according to IDC (Data Age 2025:&lt;br&gt;The Digitization of the World, From Edge to Core).</span><span style="color:inherit;"><br></span></p><p style="text-align:left;"><span style="color:inherit;"><br></span></p><p style="text-align:left;"><span style="color:inherit;"><span style="font-size:24px;">Solving Challenges with an Edge Computing Platform&nbsp;</span></span></p><span style="color:inherit;">An edge computing platform solves the following challenges:</span><div><span style="color:inherit;">» Monitoring and control at the edge</span></div><div><span style="color:inherit;">» Internet of Things (IoT) and Industrial Internet of Things (IIoT) data collection and analysis</span></div><div><span style="color:inherit;">» Cloud/enterprise IT architecture issues such as performance, latency, bandwidth, security, and proximity <br></span><p style="text-align:left;"><span style="color:inherit;">&nbsp;<br></span></p><p style="text-align:left;"><span style="color:inherit;">Edge computing is important because it creates new and improved ways for industrial and enterprise-level businesses to maximize operational efficiency, improve performance and safety, automate all core business processes, and ensure always-on availability. It is a leading method to achieve full digital transformation of your business.</span></p><p style="text-align:left;"><span style="color:inherit;">Here are a few of the things edge computing can do:</span></p><p style="text-align:left;"><span style="color:inherit;">» Enhance solutions by addressing cloud computing issues such as performance, latency, bandwidth, security, and proximity.</span></p><p style="text-align:left;"><span style="color:inherit;">» Power the next industrial revolution, transforming manufacturing and services.</span></p><p style="text-align:left;"><span style="color:inherit;">» Optimize data capture and analysis at the edge to create actionable business intelligence.</span></p><p style="text-align:left;"><span style="color:inherit;">» Create a flexible, scalable, secure, and more automated technology, systems, and core business process environment.</span></p><p style="text-align:left;"><span style="color:inherit;">» Promote an agile business ecosystem that is more efficient, performs faster, saves costs, and is easier to manage and maintain.&nbsp;</span></p><p style="text-align:left;"><span style="color:inherit;"><br></span></p><p style="text-align:left;"><span style="color:inherit;"><br></span></p><p style="text-align:left;"><span style="color:inherit;">Ref: Dummies journal book&nbsp;<br></span></p></div></div>
</div><div data-element-id="elm_RRdul_SlRDmMc8MOPWhmdw" data-element-type="button" class="zpelement zpelem-button "><style> [data-element-id="elm_RRdul_SlRDmMc8MOPWhmdw"].zpelem-button{ border-radius:1px; } </style><div class="zpbutton-container zpbutton-align-center "><style type="text/css"></style><a class="zpbutton-wrapper zpbutton zpbutton-type-primary zpbutton-size-md zpbutton-style-none " href="/contact"><span class="zpbutton-content">Get Started Now</span></a></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Mon, 31 Jan 2022 14:12:59 +0530</pubDate></item><item><title><![CDATA[Energy Conservation and Efficiency Optimization techniques]]></title><link>https://www.edrpower.com/blogs/post/energy-conservation-and-efficiency-optimization-techniques</link><description><![CDATA[Energy conserved and saved is equivalent to energy generated. Spending on Energy conservation not only reduces energy bills, but same precious natural ]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_EaNRKGnlQOSVdwUyvRR60w" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_PznEJp5ITSy-ZBIY8lMU9Q" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_v0_1nENXRIO6CRrPCMxSvg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_X9MKohjCTYmM5Em2ZX3zNQ" data-element-type="heading" class="zpelement zpelem-heading "><style> [data-element-id="elm_X9MKohjCTYmM5Em2ZX3zNQ"].zpelem-heading { border-radius:1px; } </style><h6
 class="zpheading zpheading-style-none zpheading-align-center " data-editor="true"><span style="font-size:24px;">We should Address the challenges, effects and solutions.&nbsp;</span><span style="font-size:20px;"><br>​Power is among the most critical component of infrastructure crucial for the economic growth and welfare of nations.</span><br></h6></div>
<div data-element-id="elm_AvblNbQHR8OTTnjS83T-Eg" data-element-type="text" class="zpelement zpelem-text "><style> [data-element-id="elm_AvblNbQHR8OTTnjS83T-Eg"].zpelem-text { border-radius:1px; } </style><div class="zptext zptext-align-center " data-editor="true"><p style="text-align:justify;">Energy conserved and saved is equivalent to energy generated. Spending on Energy conservation not only reduces energy bills, but same precious natural resources and reduce investments required in additional power generation capacity. In 2050 the world economy will be four time as large as today, generating an 80% increase in the amount of energy we consume. The energy intensity per square meter of the global building sector needs to improve on average by 30% by 2030 (Compared to 2015) to be on track to meet global climate ambitious set forth in the paris agreement.</p><p style="text-align:justify;"><br></p><p style="text-align:justify;">Power in India, India is the 3rd largest Producer and 2nd largest consumer of electricity in world. Installed Generation capacity is 393 GW as of Dec 2021. and demand increasing 8% average year by year. Power is among the most critical component of infrastructure crucial for the economic growth and welfare of nations.</p><p style="text-align:justify;"><br></p><p style="text-align:justify;">We should address the challenges, effects and solution.</p><blockquote style="margin:0px 0px 0px 40px;border:none;padding:0px;"><p style="text-align:justify;">1. Power Quality Monitoring ( what we can't measure we can't manage it)</p><p style="text-align:justify;">2. Energy Management System</p><p style="text-align:justify;">3. Power factor correction System</p><p style="text-align:justify;">4. Harmonics Mitigation</p><p style="text-align:justify;">5. Variable Speed Drives</p><p style="text-align:justify;">6. Thyristor Power Controller&nbsp;</p><p style="text-align:justify;">7. Energy Efficient Equipment</p><p style="text-align:justify;">8. Smart devices and Controllers</p><p style="text-align:justify;">9. Process Monitoring System</p><p style="text-align:justify;">10. Renewable and Waste energy conversion</p></blockquote></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Mon, 31 Jan 2022 14:09:19 +0530</pubDate></item><item><title><![CDATA[EDR EMS V4.0]]></title><link>https://www.edrpower.com/blogs/post/edr-ems-v4.0</link><description><![CDATA[<img align="left" hspace="5" src="https://www.edrpower.com/files/EMS-Catalogue_network link.jpg"/>EDM EMS V4.0 Platform to transform a smart meter into a real-time feedback tool for consumers.&nbsp; By Providing real-time data on electricity, water, ]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_9Douo5ACWly2fBMN1mEBwg" data-element-type="section" class="zpsection zpdefault-section zpdefault-section-bg "><style type="text/css"> [data-element-id="elm_9Douo5ACWly2fBMN1mEBwg"].zpsection{ border-radius:1px; } </style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_t23YeOtArOQFOKcjkgcm0w" data-element-type="row" class="zprow zprow-container zpalign-items-flex-start zpjustify-content-flex-start zpdefault-section zpdefault-section-bg " data-equal-column=""><style type="text/css"> [data-element-id="elm_t23YeOtArOQFOKcjkgcm0w"].zprow{ border-radius:1px; } </style><div data-element-id="elm_s31aePQ0iR9l-p26TeODsw" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- zpdefault-section zpdefault-section-bg "><style type="text/css"> [data-element-id="elm_s31aePQ0iR9l-p26TeODsw"].zpelem-col{ border-radius:1px; margin-block-start:-137px; } </style><div data-element-id="elm_qnab4tC4MUMb-iEhruaCtw" data-element-type="dividerText" class="zpelement zpelem-dividertext "><style type="text/css"> [data-element-id="elm_qnab4tC4MUMb-iEhruaCtw"] .zpdivider-container.zpdivider-text .zpdivider-common{ } [data-element-id="elm_qnab4tC4MUMb-iEhruaCtw"].zpelem-dividertext{ border-radius:1px; } </style><style></style><div class="zpdivider-container zpdivider-text zpdivider-align-center zpdivider-width100 zpdivider-line-style-solid zpdivider-style-none "><div class="zpdivider-common">Energy Management System</div>
</div></div></div></div></div></div><div data-element-id="elm_rBnv6VM2Rw-cL0S5qANEcQ" data-element-type="section" class="zpsection "><style type="text/css"> [data-element-id="elm_rBnv6VM2Rw-cL0S5qANEcQ"].zpsection{ border-radius:1px; } </style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_j2Rmd0C-Rfm41m0zLmN4kA" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"> [data-element-id="elm_j2Rmd0C-Rfm41m0zLmN4kA"].zprow{ border-radius:1px; } </style><div data-element-id="elm_yymc1bfyReOi3YteTgY4pQ" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-6 zpcol-sm-12 zpalign-self- "><style type="text/css"> [data-element-id="elm_yymc1bfyReOi3YteTgY4pQ"].zpelem-col{ border-radius:1px; } </style><div data-element-id="elm_8hFnoSOUTUCRqnx92kWu6w" data-element-type="heading" class="zpelement zpelem-heading "><style></style><h2
 class="zpheading zpheading-align-center " data-editor="true"><span style="font-size:18px;color:rgb(34, 135, 76);">Energy Conservation and Efficiency Optimization Techniques&nbsp;</span></h2></div>
<div data-element-id="elm_3f5BLaECTGeehGZ14k27Uw" data-element-type="text" class="zpelement zpelem-text "><style> [data-element-id="elm_3f5BLaECTGeehGZ14k27Uw"].zpelem-text { border-style:none; border-top-left-radius:1px; border-top-right-radius:1px; border-bottom-left-radius:1px; border-bottom-right-radius:1px; } </style><div class="zptext zptext-align-center " data-editor="true"><div style="line-height:1.2;"><div style="line-height:1.2;"><div style="line-height:1.2;"><p style="text-align:justify;"><span style="font-size:14px;text-align:center;">EDM EMS V4.0 Platform to transform a smart meter into a real-time feedback tool for consumers.&nbsp;</span><span style="font-size:14px;">By Providing real-time data on electricity, water, Fuel and Gas usage, Smart Meters allow users to make smarter decision about their energy usage&nbsp;</span><br></p><p style="text-align:left;">&nbsp;</p><p style="text-align:justify;line-height:1;"><span style="font-size:14px;">Energy Management techniques that uses energy information as a basis to eliminate waste, reduce and control current level of energy uses and improve the existing operating procedure. It minimise energy costs/waste without affecting the production and quality.</span></p><p style="text-align:justify;line-height:1;"><span style="font-size:14px;"><br></span></p><p style="text-align:justify;"></p><p style="text-align:left;"><span style="color:inherit;"><span style="font-size:14px;">EMS are Energy Management System and also called Energy Monitoring System.</span></span><br></p><p style="text-align:left;"><br></p><p style="text-align:left;"><span style="color:inherit;font-family:Arial, sans-serif;font-size:14px;">ISO 50001, the global energy management systems standard,&nbsp;<b>specifies requirements for establishing, implementing, maintaining, and improving an EnMS</b>. The standard is based upon the Plan-Do-Check-Act management system, which is familiar to many manufacturing plants that have implemented other ISO standards.</span><br></p><p style="text-align:left;"><span style="color:inherit;font-family:Arial, sans-serif;font-size:14px;"><br></span></p><p style="text-align:left;"><span style="color:inherit;font-family:Arial, sans-serif;font-size:14px;"></span></p><div style="color:inherit;"><p style="text-align:left;margin-bottom:12.5px;"><span style="font-size:14px;">ISO 50001 provides a framework of requirements for organizations to:</span></p><ul><li style="text-align:left;"><span style="font-size:14px;font-family:Arial, sans-serif;">Develop a policy for more efficient use of energy</span></li><li style="text-align:left;"><span style="font-size:14px;font-family:Arial, sans-serif;">Fix targets and objectives to meet the policy</span></li><li style="text-align:left;"><span style="font-size:14px;font-family:Arial, sans-serif;">Use data to better understand and make decisions about energy use</span></li><li style="text-align:left;"><span style="font-size:14px;font-family:Arial, sans-serif;">Measure the results</span></li><li style="text-align:left;"><span style="font-size:14px;font-family:Arial, sans-serif;">Review how well the policy works, and</span></li><li style="text-align:left;"><span style="font-size:14px;font-family:Arial, sans-serif;">Continually improve energy management.</span></li></ul><div style="text-align:left;"><span style="font-family:Arial, sans-serif;font-size:14px;"><br></span></div><div style="text-align:left;"><span style="font-family:Arial, sans-serif;font-size:14px;"><br></span></div><div style="text-align:left;"><span style="font-family:Arial, sans-serif;font-size:14px;">By</span></div><div style="text-align:left;"><span style="font-family:Arial, sans-serif;font-size:14px;">Project Department</span></div><div style="text-align:left;"><span style="font-family:Arial, sans-serif;font-size:14px;">EDR Power Integrators</span></div></div><p style="text-align:left;"><span style="color:inherit;"><br></span></p><p></p><p style="text-align:justify;"><span style="font-size:14px;"></span></p></div><p></p><p style="text-align:justify;"><span style="font-size:14px;"></span></p></div><p></p><p style="text-align:justify;"><span style="font-size:14px;"></span></p></div><p style="text-align:justify;"><span style="font-size:14px;"></span></p></div>
</div><div data-element-id="elm_F6vjDeiLQ_g-Etubpew7xg" data-element-type="row" class="zprow zprow-container zpalign-items-flex-start zpjustify-content-flex-start zpdefault-section zpdefault-section-bg " data-equal-column=""><style type="text/css"> [data-element-id="elm_F6vjDeiLQ_g-Etubpew7xg"].zprow{ border-radius:1px; } </style><div data-element-id="elm_LmGcTxbPeEcaKo0opphFWA" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- zpdefault-section zpdefault-section-bg "><style type="text/css"> [data-element-id="elm_LmGcTxbPeEcaKo0opphFWA"].zpelem-col{ border-radius:1px; } </style></div>
</div></div><div data-element-id="elm_-hvCEWcQfFIsBbniwdFWQA" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-6 zpcol-sm-12 zpalign-self- zpdefault-section zpdefault-section-bg "><style type="text/css"> [data-element-id="elm_-hvCEWcQfFIsBbniwdFWQA"].zpelem-col{ border-radius:1px; } </style><div data-element-id="elm_98RcbEOrRc-nQNo3l51nVQ" data-element-type="row" class="zprow zprow-container zpalign-items-flex-start zpjustify-content-flex-start zpdefault-section zpdefault-section-bg " data-equal-column=""><style type="text/css"> [data-element-id="elm_98RcbEOrRc-nQNo3l51nVQ"].zprow{ border-radius:1px; } </style><div data-element-id="elm_p4zKdu1p6Ry-EIQPjGhB4A" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- zpdefault-section zpdefault-section-bg "><style type="text/css"> [data-element-id="elm_p4zKdu1p6Ry-EIQPjGhB4A"].zpelem-col{ border-radius:1px; } </style><div data-element-id="elm_GGcgDyCHcDh-JcLHE79hxw" data-element-type="text" class="zpelement zpelem-text "><style> [data-element-id="elm_GGcgDyCHcDh-JcLHE79hxw"].zpelem-text { border-radius:1px; margin-block-start:49px; } </style><div class="zptext zptext-align-left " data-editor="true"><div style="line-height:1;"><p><span style="font-size:14px;font-family:Arial, sans-serif;">Feature:</span></p><p><span style="font-size:14px;font-family:Arial, sans-serif;">- Real-time Monitoring</span></p><p><span style="font-size:14px;font-family:Arial, sans-serif;">- On-line Trends &amp; Deep Analysis</span></p><p><span style="font-size:14px;font-family:Arial, sans-serif;">- Historical view Data&nbsp;Exploration</span></p><p><span style="font-size:14px;font-family:Arial, sans-serif;">- Dashboard for Data&nbsp;Visualisation</span></p><p><span style="font-size:14px;font-family:Arial, sans-serif;">- Process Data and Alert Notification</span></p><p><span style="font-size:14px;font-family:Arial, sans-serif;">- Web based View in PC and mobile</span></p><p><span style="font-size:14px;font-family:Arial, sans-serif;">- SLD / Power Flow Diagram</span></p><p><span style="font-size:14px;font-family:Arial, sans-serif;">- SMS / E-mail Alert</span></p><p><span style="font-size:14px;font-family:Arial, sans-serif;">- Minutely&nbsp;/ Hourly / Weekly / Monthly Reports</span></p><p><span style="font-size:14px;font-family:Arial, sans-serif;">- Modern time-series platform</span></p><p><span style="font-size:14px;font-family:Arial, sans-serif;">- Security and authorization</span></p><p><span style="font-size:14px;font-family:Arial, sans-serif;">- User Friendly &amp; Attractive UI</span></p><p><span style="font-size:14px;font-family:Arial, sans-serif;">- High Precision&nbsp;data &amp; Fast Loading</span></p><p><span style="font-size:14px;font-family:Arial, sans-serif;">- Cloud up-gradation, Usage&nbsp;based service</span></p><p><span style="font-size:14px;font-weight:600;font-family:Arial, sans-serif;"><br></span></p><p><span style="font-size:14px;font-weight:600;font-family:Arial, sans-serif;"><br></span></p><p><span style="font-size:14px;font-family:Arial, sans-serif;">In Industry:</span></p><p><span style="font-size:14px;font-family:Arial, sans-serif;">You have to monitor what is energy is received, refined &amp; metered &amp; distributed next to all the loads.&nbsp;</span></p><p><span style="font-size:14px;font-family:Arial, sans-serif;"><br></span></p><p><span style="font-size:14px;font-family:Arial, sans-serif;">PRIORITIZE ENERGY CONSERVATION FIRST</span></p><p><span style="font-size:14px;font-family:Arial, sans-serif;"><br></span></p><p><span style="font-family:Arial, sans-serif;font-size:14px;">Production Machine Monitoring, Utility Machines Monitoring, Transformer Utility, Blower Utility, Compressor Monitoring, Motor VFD Drives Monitoring, Pump Utility, Boiler Utility.</span></p><p><span style="font-family:Arial, sans-serif;font-size:14px;"><br></span></p><p><span style="font-family:Arial, sans-serif;font-size:14px;">What we can't measure we can't Mange it.</span></p><p><span style="font-family:Arial, sans-serif;font-size:14px;">So EMS System helps, monitor and control Energy in real time.</span></p><p><span style="font-family:Arial, sans-serif;font-size:14px;"><br></span></p><p><span style="font-family:Arial, sans-serif;font-size:14px;">BEE recommends to Energy Meter for any motor above 10HP for two shifts a day or 6000 hrs/year</span></p></div></div>
</div></div></div></div></div></div></div><div data-element-id="elm_4alqQff1PKMkhi_ZGfNY1A" data-element-type="section" class="zpsection zpdefault-section zpdefault-section-bg "><style type="text/css"> [data-element-id="elm_4alqQff1PKMkhi_ZGfNY1A"].zpsection{ border-radius:1px; } </style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_jR1F2T0bP5ajKuoAh-hL7Q" data-element-type="row" class="zprow zprow-container zpalign-items-flex-start zpjustify-content-flex-start zpdefault-section zpdefault-section-bg " data-equal-column=""><style type="text/css"> [data-element-id="elm_jR1F2T0bP5ajKuoAh-hL7Q"].zprow{ border-radius:1px; } </style><div data-element-id="elm_StowLO2cjXuuKOYp3zz1gg" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- zpdefault-section zpdefault-section-bg "><style type="text/css"> [data-element-id="elm_StowLO2cjXuuKOYp3zz1gg"].zpelem-col{ border-radius:1px; } </style><div data-element-id="elm_v41Poqir3jFhy6rB21khqA" data-element-type="buttonicon" class="zpelement zpelem-buttonicon "><style> [data-element-id="elm_v41Poqir3jFhy6rB21khqA"].zpelem-buttonicon{ border-radius:1px; } </style><div class="zpbutton-container zpbutton-align-center "><style type="text/css"></style><a class="zpbutton-wrapper zpbutton zpbutton-type-primary zpbutton-size-md zpbutton-style-none zpbutton-icon-align-left " href="/contact"><span class="zpbutton-icon "><svg viewBox="0 0 1792 1792" height="1792" width="1792" xmlns="http://www.w3.org/2000/svg"><path d="M1600 1240q0 27-10 70.5t-21 68.5q-21 50-122 106-94 51-186 51-27 0-53-3.5t-57.5-12.5-47-14.5-55.5-20.5-49-18q-98-35-175-83-127-79-264-216T344 904q-48-77-83-175-3-9-18-49t-20.5-55.5-14.5-47-12.5-57.5-3.5-53q0-92 51-186 56-101 106-122 25-11 68.5-21t70.5-10q14 0 21 3 18 6 53 76 11 19 30 54t35 63.5 31 53.5q3 4 17.5 25t21.5 35.5 7 28.5q0 20-28.5 50t-62 55-62 53-28.5 46q0 9 5 22.5t8.5 20.5 14 24 11.5 19q76 137 174 235t235 174q2 1 19 11.5t24 14 20.5 8.5 22.5 5q18 0 46-28.5t53-62 55-62 50-28.5q14 0 28.5 7t35.5 21.5 25 17.5q25 15 53.5 31t63.5 35 54 30q70 35 76 53 3 7 3 21z"></path></svg></span><span class="zpbutton-content">Enquiry Call Now</span></a></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Wed, 13 Jan 2021 23:39:59 +0530</pubDate></item><item><title><![CDATA[EMS for Substation]]></title><link>https://www.edrpower.com/blogs/post/ems</link><description><![CDATA[Integration : Energy Meter, Multifunction Meter, MDC, EB Sub-Meter, Breaker Feeders: HT Incomer, DG set, Solar Generation, MV Panel, PCC, MCC, LT Panel ]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_nvg60K_1RhaFKVakSIZzLw" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_BaCiPwy-RimaBGCLgLBaTw" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_zTOqYlGUQMygj2kmvaVQYA" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"> [data-element-id="elm_zTOqYlGUQMygj2kmvaVQYA"].zpelem-col{ border-radius:1px; } </style><div data-element-id="elm_0OReodZVRgKdwUzzuXUjWw" data-element-type="heading" class="zpelement zpelem-heading "><style> [data-element-id="elm_0OReodZVRgKdwUzzuXUjWw"].zpelem-heading { border-radius:1px; } </style><h2
 class="zpheading zpheading-align-center " data-editor="true">EMS - Energy Monitoring System</h2></div>
<div data-element-id="elm_oQZqGPogQBSOMKiS7oSLuQ" data-element-type="text" class="zpelement zpelem-text "><style> [data-element-id="elm_oQZqGPogQBSOMKiS7oSLuQ"].zpelem-text { border-radius:1px; } </style><div class="zptext zptext-align-left " data-editor="true"><div style="line-height:1;"><div><div style="line-height:1;"><p></p><div style="text-align:center;"></div><p></p><div style="line-height:1.2;"><p></p><div style="text-align:center;"><br></div><div style="text-align:center;">Integration : Energy Meter, Multifunction Meter, MDC, EB Sub-Meter, Breaker</div><div style="text-align:center;">Feeders: HT Incomer, DG set, Solar Generation, MV Panel, PCC, MCC, LT Panel</div><p></p><p style="text-align:center;">Communication Protocol: MODBUS RTU, TCP, Profibus</p><p style="text-align:center;">Parameters: Voltage, Current, Power, Energy, Frequency, PF, Load On hr, Idle hr</p><p><br></p><p><span style="color:inherit;font-weight:bold;">Know Where Your Energy Is Going</span></p><p>When’s the last time your plant conducted an energy audit? If you’re like most manufacture? not very recently—if you’ve ever done one at all. It’s great to want to go green and shift to renewable energy sources, but if you don’t know&nbsp;<span style="font-weight:bold;">what processes or areas in your buildings typically consume most of the energy</span>, your efforts won’t amount to much. It would be like trying to create a household budget without knowing how much your monthly bills are.<br></p><p style="margin-bottom:15px;">If your equipment or building is out-of-date or inefficient, it’s probably burning through your energy usage. At some point you’ll need to consider the long-term financial advantages and disadvantages of each course of action: letting the equipment continue to operate at higher cost, or biting the bullet on up-front expenses and upgrading to lower-energy systems with potential for lifetime cost savings.</p><p style="margin-bottom:15px;">Set Target to Reduce Energy Consumption, Corrective action.</p><p style="margin-bottom:15px;"><span style="font-weight:bold;">Energy Management System Benefits</span></p><p style="margin-bottom:15px;line-height:1.2;"><span style="font-size:14px;font-family:Arial, sans-serif;">- Measure and Monitor energy use to identify where to improve efficiency.</span></p><p style="margin-bottom:15px;line-height:1.2;"><span style="font-size:14px;font-family:Arial, sans-serif;">- Improve overall performance to cut energy consumption and bill.</span></p><p style="margin-bottom:15px;line-height:1.2;"><span style="font-size:14px;font-family:Arial, sans-serif;">- Minimise energy costs/waste without affection production and quality</span></p><p style="margin-bottom:15px;line-height:1.2;"><span style="font-size:14px;font-family:Arial, sans-serif;">- Reduce carbon emissions and meet government reduction targets</span></p><p style="margin-bottom:15px;line-height:1.2;"><span style="font-size:14px;font-family:Arial, sans-serif;">- Increase assurance of legal, internal compliance.</span></p><p style="margin-bottom:15px;line-height:1.2;"><span style="font-size:14px;font-family:Arial, sans-serif;">- Helps to meet any self-imposed targets your organisation has set</span></p><p style="margin-bottom:15px;line-height:1.2;"><span style="font-size:14px;font-family:Arial, sans-serif;">- Identify and Manage the risks surrounding your future energy suppl</span></p><p style="margin-bottom:15px;line-height:1.2;"></p></div><p style="margin-bottom:15px;line-height:1.2;"></p></div></div></div></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Tue, 25 Aug 2020 22:19:47 +0530</pubDate></item></channel></rss>