<?xml version="1.0" encoding="UTF-8" ?><!-- generator=Zoho Sites --><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:content="http://purl.org/rss/1.0/modules/content/"><channel><atom:link href="https://www.edrpower.com/blogs/tag/level-indicator/feed" rel="self" type="application/rss+xml"/><title>EDR POWER INTEGRATORS - Blog #level indicator</title><description>EDR POWER INTEGRATORS - Blog #level indicator</description><link>https://www.edrpower.com/blogs/tag/level-indicator</link><lastBuildDate>Wed, 15 Apr 2026 05:49:33 +0530</lastBuildDate><generator>http://zoho.com/sites/</generator><item><title><![CDATA[Level Measurement]]></title><link>https://www.edrpower.com/blogs/post/level-Measurement</link><description><![CDATA[Level Measurement: In the modern manufacturing industries which use many solvents, chemicals, steam and other liquids, and the power plants which use ]]></description><content:encoded><![CDATA[<div class="zpcontent-container blogpost-container "><div data-element-id="elm_2rUgh0QVRqyUbvwHc0bAog" data-element-type="section" class="zpsection "><style type="text/css"></style><div class="zpcontainer-fluid zpcontainer"><div data-element-id="elm_TB1UKeshTdi0Y0IoEl1ysA" data-element-type="row" class="zprow zprow-container zpalign-items- zpjustify-content- " data-equal-column=""><style type="text/css"></style><div data-element-id="elm_L0WmmMA-RyusaZqsE_00og" data-element-type="column" class="zpelem-col zpcol-12 zpcol-md-12 zpcol-sm-12 zpalign-self- "><style type="text/css"></style><div data-element-id="elm_RIS6qnhmQfO0PRua-dnOFQ" data-element-type="heading" class="zpelement zpelem-heading "><style> [data-element-id="elm_RIS6qnhmQfO0PRua-dnOFQ"].zpelem-heading { border-radius:1px; margin-block-start:4px; } </style><h2
 class="zpheading zpheading-align-center " data-editor="true"><span style="font-size:18px;">Water, Diesel, Oxygen, Oil, Fuel, Chemical, Solids</span></h2></div>
<div data-element-id="elm_sw0KXPcqQnmg7eF2Q_-wjg" data-element-type="text" class="zpelement zpelem-text "><style> [data-element-id="elm_sw0KXPcqQnmg7eF2Q_-wjg"].zpelem-text { border-radius:1px; } </style><div class="zptext zptext-align-left " data-editor="true"><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><div><div style="line-height:1;"><p style="line-height:1.5;">Level Measurement: In the modern manufacturing industries which use many solvents, chemicals, steam and other liquids, and the power plants which use vast amount of water, the accurate measurement of liquid level is very essential.</p><p style="line-height:1.5;"><br></p></div></div></div></div></div><blockquote style="margin-left:40px;border:none;"><div><div><div style="line-height:1.2;"><div><div style="line-height:1;"><p style="line-height:1.5;">Medium: Water, Effluent water, Oil, Diesel, Furnace Oil, Fuel, liquid Oxygen, Chemical and Solids.</p></div></div></div></div></div></blockquote><blockquote style="margin-left:40px;border:none;"><div><div><div style="line-height:1.2;"><div><div><p style="line-height:1.2;">Application: Level Indicator, Metering, initiate an Alarm, start or stop a pump, open or shunt a valve at a high or low level</p><p style="line-height:1.2;">Instrument: Transmitter, Indicator, Gauges, Switches, Controller</p></div></div></div></div></div></blockquote><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><div style="line-height:1.2;"><p style="line-height:1.5;"><br></p><p style="line-height:1.5;">Level Measuring Instrument (Direct&nbsp; / Indirect)</p></div></div></div></div></div></div></div></div></div></div></div></div></div><blockquote style="margin-left:40px;border:none;"><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><div style="line-height:1.2;"><p style="line-height:1.5;"><span>Method: Continuous Level Measurement, Limit Level Measurement (max/min/mid, low/high)</span></p></div></div></div></div></div></div></div></div></div></div></div></div></div></blockquote><blockquote style="margin-left:40px;border:none;"><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><div style="line-height:1.2;"><p style="line-height:1.5;"><br></p></div></div></div></div></div></div></div></div></div></div></div></div></div><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><div style="line-height:1.2;"><p><span>A) Continuous Level Measurement: ( Full Range)</span></p><ul><li><span>Measuring the level of substance in full range continuously, actual/ present level, exact amount volume, and accurate reading. It is best method of accurate measurement what is present value and how much quantity now. Easily integration with process controller, remote display indicator, PLC.</span></li><li><span>Direct Methods: Sight glass, bob and tape method in open tanks, tubular glass, Hook gauge, magnetic gauge.&nbsp;</span></li><li>Type of measurement: Capacitive type, Differential Pressure, Pressure, Float type, Magnetic Contact, Ultrasonic, Radar,&nbsp; etc.</li></ul></div></div></div></div></div></div></div></div></div></div></div></div></div></blockquote><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><blockquote style="margin-left:40px;border:none;"><div><div style="line-height:1;"><ul><li>Transmitter: Water Level Transmitter, Oil Level Transmitter, Fuel Level Transmitter, Oxygen Tank Level Transmitter, Chemical Tank Level Transmitter, Solid level Transmitter, Chemical Level Transmitter</li><li>Differential Pressure: DP Transmitter to liquid Oxygen tank level measurement, Water Level, Oil Level. Most suitable for Closed Tank, boiler drum, high pressure heater, pressurised vessel, water &amp; Steam, Minimum error.</li></ul></div></div><div><div style="line-height:1;"><ul><div style="line-height:1;"><br></div></ul>B) Limit Level Measurement: ( Max /Min /Mid, low/high)<br><ul><li>Limit Level Switch: Magnetic float Sensor, Float type level switch Capacitive Level Sensor, Float type switch, Over flow Switch, low level Switch, high level switch, level Sensor, Water level sensor, oil level sensor, Diesel level sensor, fuel level sensor, Furnace oil level sensor, Water Level Switch, Oil level switch, Diesel Level Switch</li></ul>​<br></div></div></blockquote></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div><blockquote style="margin:0px 0px 0px 40px;border:none;padding:0px;"><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><div><div><div><div><div style="line-height:1;"><ul><li>Electrical Supply: 230V AC, 110V AC, 24V DC, 48V DC</li><li>Analog Output: 4-20 mA DC, 0-10 V DC, 0-5V DC, mV, V, (user specified)</li><li>Relay Output: SPST, SPDT (1C/O, 2 C/O) / (NO+NC), Normally open, Normally Closed</li><li>Communication output: Modbus RTU, Modbus TCP, HART, Profibus,&nbsp;</li><li>Length of Measurement: upto 1000 mm / 2000 mm / 3000 mm (user specified), High level, High High level, Low level, Low level level</li><li>Process control valves: Solenoid Valve, Electrical Actuator, Rotary Actuator</li><li>Process connection: Threaded (NPT, BSP, BSPT), Flanges</li></ul><p><br></p></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div></blockquote><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><div><div><div style="line-height:1.2;"><div><div style="line-height:1;"><p style="line-height:1.2;"><br></p></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div></div>
</div></div></div></div></div></div> ]]></content:encoded><pubDate>Sat, 03 Sep 2022 15:09:59 +0530</pubDate></item></channel></rss>